Focus on the Internet of Things, sensor design-manufacturing-technical solutions!

Engineering Department:+86-510-85382096    |     中文

%{tishi_zhanwei}%

Installation of LVG726T dynamic tilt sensor for posture control during construction of rotary drilling rig

The inclination sensor is installed at the end of the drill rod, which can achieve real-time dual-axis attitude measurement under the motion conditions of the drill rod structure. The inclination sensor installed on the chassis of the vehicle can accurately measure the attitude of the vehicle body relative to the horizontal plane.

Automated Monitoring Plan for the Safety of Ancient Building Protection Against Inclined Settlement

The main monitoring object of ancient building structures is settlement. The parameter indicators need to be collected from the site physical quantities through corresponding sensors and demodulators, and the data is transmitted to the remote monitoring center database via Ethernet or wireless network. Data processing and analysis are carried out through the structural safety monitoring system software on the upper computer.

Monitoring of tunnel settlement and deformation using static level instruments

Static level gauges for settlement and deformation at the tunnel bottom are evenly arranged at 10m intervals on the tunnel floor and the side lining walls within a range of 150 meters from the tunnel entrance in both left and right tunnels, to monitor the settlement and vertical deformation of the tunnel.

Monitoring the sway posture of wind turbine tower tubes

By monitoring the three-dimensional acceleration, angle, and other data of the wind turbine tower, the posture of the wind turbine tower can be monitored.

Subway track settlement inclinometer monitoring

Project Background With the rapid economic development, many cities in our country have gradually increased the construction of urban subway systems. The construction of urban subway underground excavation tunnel projects must be carried out within the geological body. Regardless of the depth, the excavation of tunnels will inevitably disturb the underground geological body, leading to the destruction of the original equilibrium state and gradually shifting towards a new equilibrium state. Excavating the underground geological body will inevitably cause surface settlement and deformation. When the surface settlement reaches a certain level, it will affect the normal use of underground pipelines and the safety of surface buildings. During the construction period, effective measures must be taken according to requirements to reduce settlement and deformation, ensuring the safety of surface houses, roads, and pipelines.

Tilt sensor application monitoring IoT billboard system

Msensor Sensor's tilt sensor is used to monitor the IoT billboard system. Once the tilt angle of the billboard exceeds the set safety value, the monitoring data will be transmitted in real-time via a wireless network. Based on the monitoring results, automated warnings will be issued, sending reminder messages to notify relevant departments to address various safety hazards promptly. Recently, in many cities, during severe weather such as strong winds, we have to be extra cautious when walking under these 'giants (large billboards)'. Especially in coastal cities, which are affected by typhoons every year. Msensor Sensor aims to improve urban safety management levels and facilitate regulatory units.

Static Level Gauge Settlement Online Monitoring - On-site Construction Installation Guidance

The HLI-106T type settlement monitoring static level gauge is a high-precision liquid level measuring instrument used to measure the relative settlement of various measurement points of foundations and buildings. It consists of a liquid storage tank, an ultra-high precision core, a specially customized circuit module, a protective cover, and other components. The settlement system is composed of multiple sensors of the same model, connected by vent pipes and liquid pipes between the storage tanks. The reference point is placed at a stable horizontal benchmark, and when the measurement point rises or falls relative to the reference point, it causes a change in pressure at each point. By measuring the change in sensor pressure, the rise and fall changes of each measurement point relative to the horizontal benchmark can be calculated. Applications include large construction sites.

The tilt sensor is used for monitoring and early warning of debris flows and dam landslides.

1. Overview: Landslides, mudslides, and debris flows are the main types of geological disasters in our country, with a level of harm second only to earthquakes, and they occur frequently. Their distribution is very widespread, and the degree of harm is extremely serious. According to incomplete statistics, from the founding of the country until the end of 2010, there have been more than 3,000 large-scale landslides, over 2,000 landslides, and more than 2,000 debris flows nationwide. The number of medium and small-scale landslides, mudslides, and debris flows reaches hundreds of thousands. More than 350 counties, over ten thousand villages, more than 100 large factories, 55 large mines, and over 3,000 kilometers of railway lines across the country have been severely affected by landslides, mudslides, and debris flows.

Online monitoring system for tilt failure of remote transmission tower

1. Necessity of the Project: Transmission lines are mostly overhead lines. Since the lines are suspended in the air, they need to withstand mechanical forces such as their own weight, wind, heavy rain, and ice and snow, as well as erosion from harmful gases like sand and dust. The operating conditions are extremely harsh. When transmission lines pass through adverse geological areas such as desert regions, high-salinity soil areas, mined-out areas, and landslide-prone mountainous areas, the foundations of the towers are prone to sliding, tilting, and cracking under the influence of natural environments and external conditions. This can lead to deformation, tilting, or even collapse and disconnection of the towers. The tilting of the towers causes an unbalanced force on the ground wire, resulting in changes in the stress on the towers.
< 123 >