Focus on the Internet of Things, sensor design-manufacturing-technical solutions!

Engineering Department:+86-510-85382096    |     中文

%{tishi_zhanwei}%
LVT526T Dual-Axis Tilt Sensor - Digital Type
LVT526T Dual-Axis Tilt Sensor - Digital Type
LVT526T Dual-Axis Tilt Sensor - Digital Type
+
  • LVT526T Dual-Axis Tilt Sensor - Digital Type
  • LVT526T Dual-Axis Tilt Sensor - Digital Type
  • LVT526T Dual-Axis Tilt Sensor - Digital Type

LVT526T Dual-Axis Tilt Sensor - Digital Type

Product performance indicators

Parameters

Conditions

LVT526T-10

LVT526T-30

LVT526T-60

LVT526T-90

Unit

Measurement range

 

±10

±30

±60

±90

°

Measurement axis

 

X, Y axis

X, Y axis

X, Y axis

X, Y axis

 

Zero point temperature drift

-40~85°

±0.01

±0.01

±0.01

±0.01

°/℃

Sensitivity temperature coefficient

-40~85°

≤150

≤150

≤150

≤150

ppm/℃

Frequency response

DC response

100

100

100

100

Hz

Resolution

Bandwidth 5Hz

0.01

0.01

0.01

0.01

°

Accuracy

-40~85℃

0.1

0.1

0.1

0.1

°

Long-term stability

-40~85℃

<0.12

°

Power-on startup time

Product dimensions:L90*M40*H26mm

Product electrical connection

Wire color function

Output interface

Red

White

Black

Green

Yellow

1

2

3

4

5

RS232

VCC

NC

GND

RXD

 TXD

RS485

VCC

NC

GND

(B、D-)

(A、D+)

TTL

VCC

NC

GND

RXD

TXD

 

Product electrical connection

Wire color function

Output interface

Red

RED

Black

BLACK

Green

GREEN

Yellow

YELLOW

White

WHITE

Brown

BROWN

RS422

1

2

3

4

5

6

VCC

GND

RXD-(B-)

RXD+(A+)

TXD+(A+)

TXD-(B-)

Electrical Indicators

Parameters

Conditions

Minimum Value

Typical Value

Maximum Value

Unit

Supply Voltage

 

9

12

36

V

Optional

 

5

 

Operating Current

No Load

 

30

 

mA

Operating Temperature

 

-40

 

+85

℃

Storage Temperature

 

-55

 

+125

℃

Note: For other installation methods, please refer to the product manual or consult an engineer.

Accuracy 0.1°

Measurement range 0~±90° selectable

Wide voltage input DC 9~36V (5V optional)

Output interfaces RS232, RS485, TTL, RS422, MODBUS, Profibus selectable

Baud rate 2400~115200 (configurable)

Wide temperature operation -40~85℃

IP67 protection level (IP68 customizable)

Size (L90*W40*H26mm) customizable

 
  • LVT526T is a new generation of digital small-sized MEMS tilt sensor, equipped with a dual-channel gravitational tilt unit. It measures static gravitational acceleration and dynamic angular velocity through a combination of accelerometers and dynamic gyroscopes, converting them into tilt changes. This allows for the measurement of the sensor's output tilt and pitch angle relative to the horizontal plane. Output methods include selectable RS232, RS485, TTL, RS422, and MODBUS level interface standards. With an integrated MCU control system, the sensor's output linearity is corrected, compensating for the accuracy loss due to insufficient correction in analog types.

    The product uses non-contact measurement principles, capable of real-time output of the current attitude tilt angle, making it easy to use without needing to retrieve the two surfaces for relative changes. It is an ideal choice for industrial automation control and platform attitude measurement, with strong resistance to external electromagnetic interference, suitable for long-term operation in harsh industrial environments.

    Main Features

    ● Dual-axis tilt monitoring ● Full range accuracy of 0.1°, resolution of 0.01° ● Industrial-grade design ● Wide voltage input DC 9~36V (5V optional)

    ● Wide temperature operation -40~+85℃ ● Range 0~±90° (optional) ● High vibration resistance >3500g ● Adjustable baud rate 2400~115200

    ● IP67 protection level ● Output RS232/RS485/TTL/RS422/MODBUS (optional) ● Small size (90*40*26mm) (customizable)

    Product Applications

    ● High voltage power line tower monitoring ● Satellite solar antenna positioning ● Tractors, deep tillage agricultural machinery ● Mining machinery, oil logging equipment ● Medical equipment

    ● Gimbal leveling ● Hydraulic lift platform ● Based on tilt monitoring ● Various engineering machinery angle control ● Bridge dam monitoring

  • Product performance indicators

    Parameters

    Conditions

    LVT526T-10

    LVT526T-30

    LVT526T-60

    LVT526T-90

    Unit

    Measurement range

     

    ±10

    ±30

    ±60

    ±90

    °

    Measurement axis

     

    X, Y axis

    X, Y axis

    X, Y axis

    X, Y axis

     

    Zero point temperature drift

    -40~85°

    ±0.01

    ±0.01

    ±0.01

    ±0.01

    °/℃

    Sensitivity temperature coefficient

    -40~85°

    ≤150

    ≤150

    ≤150

    ≤150

    ppm/℃

    Frequency response

    DC response

    100

    100

    100

    100

    Hz

    Resolution

    Bandwidth 5Hz

    0.01

    0.01

    0.01

    0.01

    °

    Accuracy

    -40~85℃

    0.1

    0.1

    0.1

    0.1

    °

    Long-term stability

    -40~85℃

    <0.12

    °

    Power-on startup time

  • Product dimensions:L90*M40*H26mm

    Product electrical connection

    Wire color function

    Output interface

    Red

    White

    Black

    Green

    Yellow

    1

    2

    3

    4

    5

    RS232

    VCC

    NC

    GND

    RXD

     TXD

    RS485

    VCC

    NC

    GND

    (B、D-)

    (A、D+)

    TTL

    VCC

    NC

    GND

    RXD

    TXD

     

    Product electrical connection

    Wire color function

    Output interface

    Red

    RED

    Black

    BLACK

    Green

    GREEN

    Yellow

    YELLOW

    White

    WHITE

    Brown

    BROWN

    RS422

    1

    2

    3

    4

    5

    6

    VCC

    GND

    RXD-(B-)

    RXD+(A+)

    TXD+(A+)

    TXD-(B-)

  • Electrical Indicators

    Parameters

    Conditions

    Minimum Value

    Typical Value

    Maximum Value

    Unit

    Supply Voltage

     

    9

    12

    36

    V

    Optional

     

    5

     

    Operating Current

    No Load

     

    30

     

    mA

    Operating Temperature

     

    -40

     

    +85

    ℃

    Storage Temperature

     

    -55

     

    +125

    ℃

  • Note: For other installation methods, please refer to the product manual or consult an engineer.

  • Accuracy 0.1°

    Measurement range 0~±90° selectable

    Wide voltage input DC 9~36V (5V optional)

    Output interfaces RS232, RS485, TTL, RS422, MODBUS, Profibus selectable

    Baud rate 2400~115200 (configurable)

    Wide temperature operation -40~85℃

    IP67 protection level (IP68 customizable)

    Size (L90*W40*H26mm) customizable

     
  • File size: 2.6MB