Product performance indicators

Parameters

Conditions

LVT416T-10

LVT416T-30

LVT416T-60

LVT416T-90

Unit

Measurement range

 

±10

±30

±60

±90

°

Measurement axis

YAxis selectable

XAxis

XAxis

XAxis

XAxis

 

Zero point temperature drift

-40~85°

±0.05

±0.05

±0.05

±0.05

°/℃

Sensitivity temperature coefficient

-40~85°

≤200

≤200

≤200

≤200

ppm/℃

Frequency response

DC response

100

100

100

100

Hz

Resolution

Bandwidth 5Hz

0.05

0.05

0.05

0.05

°

Accuracy

-40~85℃

0.25

°

Long-term stability

-40~85℃

<0.3

°

Power-on startup time

 

0.2

 

Product dimensions:L55*M37*H24mm

 

 

Product electrical connection

Wire color function

Output interface

Red

RED

Black

BLACK

Green

GREEN

Yellow

YELLOW

White

WHITE

Brown

BROWN

RS422

1

2

3

4

5

6

VCC

GND

RXD-(B-)

RXD+(A+)

TXD+(A+)

TXD-(B-)

 

Product electrical connection

Wire color function

Output interface

RedRED

WhiteWHITE

BlackBLACK

GreenGREEN

YellowYELLOW

1

2

3

4

5

RS232

VCC

NC

GND

RXD

 TXD

RS485

VCC

NC

GND

(B,D-)

(A,D+)

TTL

VCC

NC

GND

RXD

TXD

Electrical Indicators

Parameters

Conditions

Minimum Value

Typical Value

Maximum Value

Unit

Supply Voltage

 

 

5

 

V

Optional

9

12

36

Operating Current

No Load

 

30

 

mA

Operating Temperature

 

-40

 

+85

℃

Storage Temperature

 

-55

 

+125

℃

Note: For other installation methods, please refer to the product manual or consult an engineer.

Accuracy 0.25°

Range 0~±180° optional

Input voltage DC +5V (9~36V optional)

Output interface RS232, RS485, TTL, RS422, MODBUS, Profibus optional

Baud rate 2400~115200 (configurable)

Wide temperature operation -40~85℃

IP67 protection level (IP68 customizable)

Size (L55*M37*H24mm) customizable

 
  • The LVT416T product is a new generation of digital small-sized MEMS tilt sensor, which has a built-in dual-channel gravitational tilt unit. It measures static gravitational acceleration and converts it into tilt changes. This allows for the measurement of the sensor's output tilt and pitch angles relative to the horizontal plane. Output methods include selectable RS232, RS485, TTL, RS422, and MODBUS level interface standards. Due to the built-in MCU control system, the sensor's output linearity is corrected a second time, compensating for the accuracy loss caused by insufficient correction in analog types.

    The product uses non-contact measurement principles, can output the current attitude tilt angle in real-time, is easy to use, and does not require finding the two surfaces for relative changes during installation. It is an ideal choice for industrial automation control and platform attitude measurement, resistant to external electromagnetic interference, and can adapt to long-term operation in harsh industrial environments.

    Main Features

    ● Single-axis tilt monitoring ● Full range accuracy of 0.25°, resolution of 0.05° ● Output frequency selectable from 5 to 100HZ ● Input voltage DC 5V (9-36V optional)

    ● Wide temperature operation -40 to +85℃ ● Range 0 to ±180° (optional) ● High vibration resistance >2500g ● Adjustable baud rate from 2400 to 115200

    ● IP67 protection level ● Output RS232/RS485/TTL/RS422/MODBUS (optional) ● Small size (55*37*24mm) (customizable)

    Product Applications

    ● Monitoring of high-voltage transmission tower poles ● Agricultural machinery, rotary drilling rigs ● Aerial work vehicles ● Mining machinery, oil logging equipment ● Medical equipment

    ● Gimbal leveling ● Hydraulic lift platforms ● Based on tilt monitoring ● Angle control of various engineering machinery ● Monitoring of bridges and dams

  • Product performance indicators

    Parameters

    Conditions

    LVT416T-10

    LVT416T-30

    LVT416T-60

    LVT416T-90

    Unit

    Measurement range

     

    ±10

    ±30

    ±60

    ±90

    °

    Measurement axis

    YAxis selectable

    XAxis

    XAxis

    XAxis

    XAxis

     

    Zero point temperature drift

    -40~85°

    ±0.05

    ±0.05

    ±0.05

    ±0.05

    °/℃

    Sensitivity temperature coefficient

    -40~85°

    ≤200

    ≤200

    ≤200

    ≤200

    ppm/℃

    Frequency response

    DC response

    100

    100

    100

    100

    Hz

    Resolution

    Bandwidth 5Hz

    0.05

    0.05

    0.05

    0.05

    °

    Accuracy

    -40~85℃

    0.25

    °

    Long-term stability

    -40~85℃

    <0.3

    °

    Power-on startup time

     

    0.2

     

  • Product dimensions:L55*M37*H24mm

     

     

    Product electrical connection

    Wire color function

    Output interface

    Red

    RED

    Black

    BLACK

    Green

    GREEN

    Yellow

    YELLOW

    White

    WHITE

    Brown

    BROWN

    RS422

    1

    2

    3

    4

    5

    6

    VCC

    GND

    RXD-(B-)

    RXD+(A+)

    TXD+(A+)

    TXD-(B-)

     

    Product electrical connection

    Wire color function

    Output interface

    RedRED

    WhiteWHITE

    BlackBLACK

    GreenGREEN

    YellowYELLOW

    1

    2

    3

    4

    5

    RS232

    VCC

    NC

    GND

    RXD

     TXD

    RS485

    VCC

    NC

    GND

    (B,D-)

    (A,D+)

    TTL

    VCC

    NC

    GND

    RXD

    TXD

  • Electrical Indicators

    Parameters

    Conditions

    Minimum Value

    Typical Value

    Maximum Value

    Unit

    Supply Voltage

     

     

    5

     

    V

    Optional

    9

    12

    36

    Operating Current

    No Load

     

    30

     

    mA

    Operating Temperature

     

    -40

     

    +85

    ℃

    Storage Temperature

     

    -55

     

    +125

    ℃

  • Note: For other installation methods, please refer to the product manual or consult an engineer.

  • Accuracy 0.25°

    Range 0~±180° optional

    Input voltage DC +5V (9~36V optional)

    Output interface RS232, RS485, TTL, RS422, MODBUS, Profibus optional

    Baud rate 2400~115200 (configurable)

    Wide temperature operation -40~85℃

    IP67 protection level (IP68 customizable)

    Size (L55*M37*H24mm) customizable

     
  • File size: 2.4MB