HDS744T Dynamic Dual-Axis 4-Way Tilt Switch
+
  • HDS744T Dynamic Dual-Axis 4-Way Tilt Switch

HDS744T Dynamic Dual-Axis 4-Way Tilt Switch

Product performance indicators

Parameters

Conditions

HDS744T

Unit

Measurement range

 

±90

°

Measurement axis

 

XY axis

 

Alarm axis

 

XY axis

 

Frequency response

DC response

100

Hz

Dynamic accuracy

-40~85℃

0.5

°

Static accuracy

-40~85℃

0.06

°

Long-term stability

-40~85℃

<0.52

°

Power-on startup time

 

0.3

S

Output signal

Switching quantity (voltage) output, RS232 and TTL selectable, RS485 customizable

Relay (normally open and normally closed) output, RS232 and TTL selectable, RS485 customizable

Average working time

≥55000hours/Times

Shock resistance

25000g, 0.5ms, 3Times/axis

Vibration resistance

10grms、10~1000Hz

Insulation resistance

≥100MΩ

Waterproof rating

IP67

Cable

Standard configuration1.5 metersLength, wear-resistant, oil-resistant, wide temperature, shielded cable8*0.3mm2

Weight

150g(excluding packaging)

Product dimensions:L60*W59*H40MM

Product electrical connection

Wire color function

Red R

Black B

Green GREEN

Yellow YELLOW

Blue OR

Brown BR

White WH

Gray PP

1

2

3

4

5

6

7

8

Relay

(Normally open and normally closed)

VCC

GND

RS232RXD

or RS485 (B, D-)

RS232TXD

or RS485 (A, D+)

X-

(2-wire)

X+

(2-wire)

Y+

(2-wire)

Y-

(2-wire)

Voltage

(Switching quantity)

VCC

GND

RS232RXD

or RS485 (B, D-)

RS232TXD

or RS485 (A, D+)

X-

RelayOut

X+

Relay Out

Y+

Relay Out

Y-

Relay Out

 

Electrical Indicators

Parameters

Conditions

Minimum Value

Typical Value

Maximum Value

Unit

Supply Voltage

Standard

9

12

36

V

Customized

 

5

 

Operating Current

 

 

45

 

mA

Maximum Current (Normally Closed)

 

 

1000

 

mA

Operating Temperature

 

-40

 

+85

℃

Storage Temperature

 

-55

 

+125

℃

Dynamic accuracy 0.5°, static accuracy: 0.06°

Measuring range: 0~±90°

Wide voltage input DC 9~36V (5V can be customized)

Switching quantity (voltage), relay output (normally open and normally closed) can also be selected

Alarm threshold and trigger delay time can be set by the user

Wide temperature operation -40~85℃

IP67 protection level (IP68 can be customized)

Size (L60*W59*H29mm) can be customized

Can measure tilt data of carriers in motion or under strong vibration conditions

  • HDS744T is a new generation MEMS dynamic tilt control switch that can measure tilt data under moving carriers or strong vibration conditions. Dynamic measurement accuracy is 0.5°, static accuracy is 0.06°, with small size, low power consumption, high consistency and stability, dual-axis 4-way tilt switch; built-in MCU control system, vertical gyroscope and accelerometer, integrated attitude resolver, using optimal digital filtering algorithm to reduce noise, combined with N-order Kalman filtering algorithm, through various compensations such as nonlinear compensation, orthogonal compensation, and temperature drift, to eliminate error sources and improve measurement accuracy.

    The product design is precise, with additional compensation for temperature and linearity, integrating comprehensive protection functions such as short circuit, instantaneous high voltage, polarity, and surge. Each process is precise and rigorous, ensuring reliability under different working conditions and long-term use; it has 4 sets of relay output circuits (normally open and normally closed contacts). When the tilt value exceeds the preset alarm threshold, it will output a relay signal (driving current 1A) or a voltage signal (output voltage = supply voltage) to drive solenoid valves to shut down hydraulic systems, buzzers, alarm lights... automatically alerting personnel for safe operation, widely used in the field of industrial automation control.

    Main Features

    ● Dual-axis tilt monitoring (0-±90°) ● Dynamic accuracy 0.5°, static accuracy 0.06° ● Input vertical gyroscope, N-order Kalman filtering ● Input voltage DC 9~36V (5V customizable)

    ● Wide temperature operation -40 to +85℃ ● Alarm threshold and trigger delay time can be set by the user ● High nonlinear compensation, orthogonal compensation, temperature compensation ● IP67 protection level (IP68 customizable)

    ● Switch quantity (voltage), relay output (normally open and normally closed) can also be selected ● Small size (60*59*29mm) (customizable)

    Product Applications

    ● Balance scooters ● Agricultural machinery, rotary drilling rigs ● AGV carts ● Mining machinery, oil logging equipment ● Medical equipment

    ● Forklifts, robot tilting ● Hydraulic lifting platforms ● Based on tilt monitoring ● Various engineering machinery angle control ● Forklifts, pile foundations, hydraulic unloading machines

  • Product performance indicators

    Parameters

    Conditions

    HDS744T

    Unit

    Measurement range

     

    ±90

    °

    Measurement axis

     

    XY axis

     

    Alarm axis

     

    XY axis

     

    Frequency response

    DC response

    100

    Hz

    Dynamic accuracy

    -40~85℃

    0.5

    °

    Static accuracy

    -40~85℃

    0.06

    °

    Long-term stability

    -40~85℃

    <0.52

    °

    Power-on startup time

     

    0.3

    S

    Output signal

    Switching quantity (voltage) output, RS232 and TTL selectable, RS485 customizable

    Relay (normally open and normally closed) output, RS232 and TTL selectable, RS485 customizable

    Average working time

    ≥55000hours/Times

    Shock resistance

    25000g, 0.5ms, 3Times/axis

    Vibration resistance

    10grms、10~1000Hz

    Insulation resistance

    ≥100MΩ

    Waterproof rating

    IP67

    Cable

    Standard configuration1.5 metersLength, wear-resistant, oil-resistant, wide temperature, shielded cable8*0.3mm2

    Weight

    150g(excluding packaging)

  • Product dimensions:L60*W59*H40MM

    Product electrical connection

    Wire color function

    Red R

    Black B

    Green GREEN

    Yellow YELLOW

    Blue OR

    Brown BR

    White WH

    Gray PP

    1

    2

    3

    4

    5

    6

    7

    8

    Relay

    (Normally open and normally closed)

    VCC

    GND

    RS232RXD

    or RS485 (B, D-)

    RS232TXD

    or RS485 (A, D+)

    X-

    (2-wire)

    X+

    (2-wire)

    Y+

    (2-wire)

    Y-

    (2-wire)

    Voltage

    (Switching quantity)

    VCC

    GND

    RS232RXD

    or RS485 (B, D-)

    RS232TXD

    or RS485 (A, D+)

    X-

    RelayOut

    X+

    Relay Out

    Y+

    Relay Out

    Y-

    Relay Out

     

  • Electrical Indicators

    Parameters

    Conditions

    Minimum Value

    Typical Value

    Maximum Value

    Unit

    Supply Voltage

    Standard

    9

    12

    36

    V

    Customized

     

    5

     

    Operating Current

     

     

    45

     

    mA

    Maximum Current (Normally Closed)

     

     

    1000

     

    mA

    Operating Temperature

     

    -40

     

    +85

    ℃

    Storage Temperature

     

    -55

     

    +125

    ℃

  • Dynamic accuracy 0.5°, static accuracy: 0.06°

    Measuring range: 0~±90°

    Wide voltage input DC 9~36V (5V can be customized)

    Switching quantity (voltage), relay output (normally open and normally closed) can also be selected

    Alarm threshold and trigger delay time can be set by the user

    Wide temperature operation -40~85℃

    IP67 protection level (IP68 can be customized)

    Size (L60*W59*H29mm) can be customized

    Can measure tilt data of carriers in motion or under strong vibration conditions

  • File size: 1.4MB