Focus on the Internet of Things, sensor design-manufacturing-technical solutions!

Engineering Department:+86-510-85382096    |     中文

%{tishi_zhanwei}%
HMI-CX400 Fixed Inclinometer
HMI-CX400 Fixed Inclinometer
HMI-CX400 Fixed Inclinometer
+
  • HMI-CX400 Fixed Inclinometer
  • HMI-CX400 Fixed Inclinometer
  • HMI-CX400 Fixed Inclinometer

HMI-CX400 Fixed Inclinometer

Product performance indicators

Parameters

Conditions

HMI-CX400

Unit

Measurement range

 

±10

±30

±60

±90

°

Measurement axis

 

X, Y axis

X, Y axis

X, Y axis

X, Y axis

 

Zero point temperature drift

-40~85°

±0.001

±0.001

±0.001

±0.001

°/℃

Sensitivity temperature coefficient

-40~85°

≤100

≤100

≤100

≤100

ppm/℃

Frequency response

DC response

100

100

100

100

Hz

Resolution

 

0.001

0.001

0.001

0.001

°

Accuracy

-40~85℃

0.01

0.02

0.03

0.05

°

Long-term stability

-40~85℃

<0.013

<0.022

<0.031

<0.054

°

Power-on startup time

 

0.2

Size

Instrument length 750mm

Instrument diameter Ф30m, aperture Ф28mm

Distance between guide wheels 480mm

 

Product electrical connection

Wire color function

Output interface

Red

White

Black

Green

Yellow

1

2

3

4

5

RS232

VCC

NC

GND

RXD

 TXD

RS485

VCC

NC

GND

(B、D-)

(A、D+)

TTL

VCC

NC

GND

RXD

TXD

Electrical Indicators

Parameters

Conditions

Minimum Value

Typical Value

Maximum Value

Unit

Supply Voltage

 

9

12

36

V

Customizable

 

5

 

Operating Current

No Load

 

40

 

mA

Operating Temperature

 

-40

 

+85

℃

Storage Temperature

 

-55

 

+125

℃

1. Place the sensor in the working space;

2. Set the initial values, the positive and negative of the X-axis, to obtain angle data;

3. Change the direction to obtain another set of data;

4. The zero point position is taken as the average value of the two sets of data.

Accuracy 0.01° (±0.3mm)

Single and dual axis, range: 0 to ±90° optional

All stainless steel, corrosion-resistant

Output interface RS232, RS485, TTL optional

Wide voltage input DC 9 to 36V (5V customizable)

Single bus structure, can be used in multiple sections in series

Waterproof performance ≥1MPa (underwater 200m)

Length 750mm, diameter Ф28mm, distance between guide wheels 480mm

  • The HMI-CX400 fixed inclinometer is developed and produced by Msensor Sensor Research and Development for situations where conventional portable inclinometers are difficult to read on-site. The measurement unit can be reused in series or parallel with the inclinometer tube, and the output signal is in RS485 Modbus protocol. It can directly display the structural offset angle at different depths of the measurement hole, and then calculate the horizontal displacement based on trigonometric relationships, while synchronously measuring the temperature at the embedded point, making it easy to connect to the customer's data acquisition system.

    Using high-precision MEMS sensors, it has high sensitivity, stable measurement performance, low temperature influence, fast stability, few installation accessories, and easy assembly. It is commonly used for automated real-time monitoring of earth-rock dams, panel dams, geotechnical slopes, embankments, and foundation pits. For example, it can be installed on a dam to monitor the safety of the dam body in real-time, as well as on dangerous high slopes that are difficult for observers to reach. Observers can obtain monitoring data by remote measurement from the observation room.

    Main Features

    ● Accuracy 0.01° (±0.3mm) ● Single and dual axis, range: 0 to ±90° optional ● All stainless steel, corrosion-resistant ● Wide voltage input DC 9 to 36V (5V customizable)

    ● Wide temperature operation -40 to +85℃ ● Range ±90° (optional) ● Single bus structure, can be used in multiple sections in series ● More compact structure, stable

    ● Waterproof performance ≥1MPa (underwater 200m) ● Output RS232/RS485/TTL (optional) ● Length 750mm, diameter Ф28mm, wheel spacing 480mm

    Product Applications

    ● Deep foundation pit inclinometer ● Slope monitoring ● Deformation of roadbed and dam body ● Deep horizontal displacement of soil around tunnels ● Inclinometer

    ● Probe well logging ● Construction and building construction ● Based on tilt monitoring ● Landslides ● Ground fissures, seabed deformation

  • Product performance indicators

    Parameters

    Conditions

    HMI-CX400

    Unit

    Measurement range

     

    ±10

    ±30

    ±60

    ±90

    °

    Measurement axis

     

    X, Y axis

    X, Y axis

    X, Y axis

    X, Y axis

     

    Zero point temperature drift

    -40~85°

    ±0.001

    ±0.001

    ±0.001

    ±0.001

    °/℃

    Sensitivity temperature coefficient

    -40~85°

    ≤100

    ≤100

    ≤100

    ≤100

    ppm/℃

    Frequency response

    DC response

    100

    100

    100

    100

    Hz

    Resolution

     

    0.001

    0.001

    0.001

    0.001

    °

    Accuracy

    -40~85℃

    0.01

    0.02

    0.03

    0.05

    °

    Long-term stability

    -40~85℃

    <0.013

    <0.022

    <0.031

    <0.054

    °

    Power-on startup time

     

    0.2

    Size

    Instrument length 750mm

    Instrument diameter Ф30m, aperture Ф28mm

    Distance between guide wheels 480mm

     

    Product electrical connection

    Wire color function

    Output interface

    Red

    White

    Black

    Green

    Yellow

    1

    2

    3

    4

    5

    RS232

    VCC

    NC

    GND

    RXD

     TXD

    RS485

    VCC

    NC

    GND

    (B、D-)

    (A、D+)

    TTL

    VCC

    NC

    GND

    RXD

    TXD

  • Electrical Indicators

    Parameters

    Conditions

    Minimum Value

    Typical Value

    Maximum Value

    Unit

    Supply Voltage

     

    9

    12

    36

    V

    Customizable

     

    5

     

    Operating Current

    No Load

     

    40

     

    mA

    Operating Temperature

     

    -40

     

    +85

    ℃

    Storage Temperature

     

    -55

     

    +125

    ℃

  • 1. Place the sensor in the working space;

    2. Set the initial values, the positive and negative of the X-axis, to obtain angle data;

    3. Change the direction to obtain another set of data;

    4. The zero point position is taken as the average value of the two sets of data.

  • Accuracy 0.01° (±0.3mm)

    Single and dual axis, range: 0 to ±90° optional

    All stainless steel, corrosion-resistant

    Output interface RS232, RS485, TTL optional

    Wide voltage input DC 9 to 36V (5V customizable)

    Single bus structure, can be used in multiple sections in series

    Waterproof performance ≥1MPa (underwater 200m)

    Length 750mm, diameter Ф28mm, distance between guide wheels 480mm

  • File size: 1.5MB