HLI-106T hydraulic static level gauge
HLI-106T hydraulic static level gauge
HLI-106T hydraulic static level gauge
HLI-106T hydraulic static level gauge
+
  • HLI-106T hydraulic static level gauge
  • HLI-106T hydraulic static level gauge
  • HLI-106T hydraulic static level gauge
  • HLI-106T hydraulic static level gauge

HLI-106T hydraulic static level gauge

Product performance indicators

Parameters

Conditions

HLI-106T

Unit

Range

 

50

100

200

1000

mmH2O

Sensitivity

 

0.01

0.01

0.01

0.01

mmH2O

Temperature influence

-40~85°

±0.3

±0.6

±0.8

±1

mmH2O

Frequency response

DC response

100

100

100

100

Hz

Resolution

 

0.01

0.01

0.01

0.01

mmH2O

Accuracy

-40~85℃

0.2

0.3

0.5

1

mmH2O

Long-term stability

-40~85℃

<0.023

<0.32

<0.51

<0.15

mmH2O

Power-on startup time

 

0.2

0.2

0.2

0.2

s

Response time

 

 

Product electrical connection

Wire color function

Output interface

Red

Black

White

Yellow

Green

1

2

3

4

5

MODBUS

VCC

GND

NC

A+

B-

RS485

Electrical Indicators

Parameters

Conditions

Minimum Value

Typical Value

Maximum Value

Unit

Supply Voltage

 

9

12

36

V

Power Consumption

No Load

 

1

 

W

Operating Temperature

 

-40

 

+85

℃

Storage Temperature

 

-55

 

+125

℃

Please install the level instrument correctly; incorrect installation can lead to measurement errors.

Product appearance diagram

 

 

Range: 0-500-2500mmH2O

Accuracy 0.2mm

Resolution 0.01mm

Output RS485/MODBUS (optional)

Wide voltage input DC9~36V

IP67 protection level

Wide temperature operation -40~+85℃

Technology from Switzerland KELLER

  • The HLI-106T type settlement monitoring static level gauge is a high-precision liquid level measuring instrument used to measure the relative settlement of various measurement points of foundations and buildings. It consists of components such as a liquid storage tank, high-precision core, specially customized circuit module, and protective cover. It is suitable for measuring small range and high precision settlement displacements.

    The static level gauge is a high-precision liquid level measuring instrument used to measure the relative settlement of various measurement points of foundations and buildings. Applications include large construction sites such as hydropower station plants, dams, high-rise buildings, nuclear power plants, hydraulic hub projects, railways, subways, high-speed rail, and the measurement of uneven settlement at various points in comprehensive utility tunnels. The HLI-106T is specifically designed for settlement monitoring in comprehensive utility tunnels.

    Main Features

    ● Range: 0-500-2500mmH2O ● Accuracy 0.2mm, Resolution 0.01mm ● Technology from Switzerland KELLER ● Wide voltage input DC9~36V

    ● Wide temperature operation -40~+85℃ ● Non-destructive overpressure 1.5 times full scale ● Baud rate adjustable from 2400~115200 ● IP67 protection level

    ● Output RS485/MODBUS (optional)

    Product Applications

    ● Monitoring of high-voltage power line towers ● Building (house) settlement ● Subway foundation pit tunnels ● Monitoring of uneven settlement measurement for foundation layers, roadbeds, embankments, bridges, buildings, subways, and bridge-road transition sections.

    ● Comprehensive utility tunnels ● Large liquid storage tanks ● Hydraulic hub projects ● Angle control of various engineering machinery ● Monitoring of bridges and dams

  • Product performance indicators

    Parameters

    Conditions

    HLI-106T

    Unit

    Range

     

    50

    100

    200

    1000

    mmH2O

    Sensitivity

     

    0.01

    0.01

    0.01

    0.01

    mmH2O

    Temperature influence

    -40~85°

    ±0.3

    ±0.6

    ±0.8

    ±1

    mmH2O

    Frequency response

    DC response

    100

    100

    100

    100

    Hz

    Resolution

     

    0.01

    0.01

    0.01

    0.01

    mmH2O

    Accuracy

    -40~85℃

    0.2

    0.3

    0.5

    1

    mmH2O

    Long-term stability

    -40~85℃

    <0.023

    <0.32

    <0.51

    <0.15

    mmH2O

    Power-on startup time

     

    0.2

    0.2

    0.2

    0.2

    s

    Response time

     

     

  • Product electrical connection

    Wire color function

    Output interface

    Red

    Black

    White

    Yellow

    Green

    1

    2

    3

    4

    5

    MODBUS

    VCC

    GND

    NC

    A+

    B-

    RS485

  • Electrical Indicators

    Parameters

    Conditions

    Minimum Value

    Typical Value

    Maximum Value

    Unit

    Supply Voltage

     

    9

    12

    36

    V

    Power Consumption

    No Load

     

    1

     

    W

    Operating Temperature

     

    -40

     

    +85

    ℃

    Storage Temperature

     

    -55

     

    +125

    ℃

  • Please install the level instrument correctly; incorrect installation can lead to measurement errors.

    Product appearance diagram

     

     

  • Range: 0-500-2500mmH2O

    Accuracy 0.2mm

    Resolution 0.01mm

    Output RS485/MODBUS (optional)

    Wide voltage input DC9~36V

    IP67 protection level

    Wide temperature operation -40~+85℃

    Technology from Switzerland KELLER

  • File size: 1.6MB