Focus on the Internet of Things, sensor design-manufacturing-technical solutions!

Engineering Department:+86-510-85382096    |     中文

%{tishi_zhanwei}%
LW126C Non-contact Angle Sensor - Digital Type
LW126C Non-contact Angle Sensor - Digital Type
LW126C Non-contact Angle Sensor - Digital Type
+
  • LW126C Non-contact Angle Sensor - Digital Type
  • LW126C Non-contact Angle Sensor - Digital Type
  • LW126C Non-contact Angle Sensor - Digital Type

LW126C Non-contact Angle Sensor - Digital Type

 

Parameter

Condition

LW126C

-90

LW126C

-180

LW126C

-270

LW126C

-360

Unit

Measurement Range

 

0~90

0~180

0~270

0~360

°

Temperature Drift

-40~85°

±0.0015

±0.0015

±0.0015

±0.0015

°/℃

Sensitivity Temperature Coefficient

-40~85°

<150

<150

<150

<150

ppm/℃

Frequency Response

DC response

100

100

100

100

Hz

Resolution

 

0.022

0.022

0.022

0.022

°

Accuracy

-40~85℃

0.3

0.5

0.6

1

°

Long-term Stability

-40~85℃

0.055

0.063

0.08

0.12

°

Output Interface

 

RS232、TTL、RS485、MODBUS optional

Power-on Start Time

Product electrical connection

Wire color function

Output interface

Red

White

Black

Green

Yellow

1

2

3

4

5

RS232

VCC

NC

GND

RXD

 TXD

RS485

VCC

NC

GND

(B, D-)

(A, D+)

TTL

VCC

NC

GND

RXD

TXD

Electrical Indicators

Parameters

Conditions

Minimum Value

Typical Value

Maximum Value

Unit

Supply Voltage

Standard

9

12

36

V

Customized

 

5

 

Operating Current(7)

 

 

35

 

mA

Power Reverse Protection(8)

 

 

40

 

V

Signal Reverse Protection(8)

 

 

40

 

V

Operating Temperature

 

-40

 

+85

℃

Storage Temperature

 

-55

 

+100

℃

 

MachineMechanical Characteristics

Connector

Lead (1.5m) Customizable

Torque

<10mN.m

Protection Level

IP66

Mechanical Angle

0~360°Unlimited rotation, bidirectional rotation without stop position

Shell Material

Shell: Aluminum alloy oxidation, back cover: Stainless steel, shaft: Stainless steel

Mechanical Life

> 120 million revolutions

Installation

Fixed with two screws,Connected to the customer's rotor with a flexible coupling

 

 

Accuracy 0.3°, Resolution 0.22°

Range 0~360° selectable

Wide voltage input DC 9~36V

Output interfaces RS232, TTL, RS485, MODBUS selectable

High shock resistance >20000g

Wide temperature operation -40~85℃

IP66 protection level (customizable)

Sampling rate 1K HZ

  • The LW126C magnetic angle sensor uses MEMS technology and processes through DSP, achieving programmable intelligent control for linearity correction, temperature compensation, standardization of output signals according to range, digital filtering, zero point setting, and multi-segment different slope settings. It operates within a range of 0 to 360°, with user-defined angles. Output interfaces: RS232, TTL, RS485, MODBUS optional.

    This sensor is powered by a supply voltage of 9V to 36V and has protection against reverse and pulse voltage spikes. Measurement error is ±0.3°, reset repeatability is 0.001mV, and absolute temperature drift is (±20 to 50μA).

    Main Features

    ● Sampling rate 1K HZ ● Full range accuracy 0.3° ● Output RS232, RS485, TTL, MODBUS optional ● Wide voltage input DC 9 to 36V

    ● Wide operating temperature -40 to +85℃ ● Angle resolution 0.022° ● High vibration resistance >20000g

    ● IP66 protection level ● Range 0 to 360° (optional) ● Linearity 0.15%~0.5%

    Product Applications

    ● Railway gauge measuring tools, gauge instruments ● Satellite solar antenna positioning ● Drag motor control ● Mining machinery, oil logging equipment ● Medical equipment

    ● Gimbal leveling ● Liquid valve: angle actuator ● Angle-based control ● Various engineering machinery angle control ● Textile machinery

  •  

  • Parameter

    Condition

    LW126C

    -90

    LW126C

    -180

    LW126C

    -270

    LW126C

    -360

    Unit

    Measurement Range

     

    0~90

    0~180

    0~270

    0~360

    °

    Temperature Drift

    -40~85°

    ±0.0015

    ±0.0015

    ±0.0015

    ±0.0015

    °/℃

    Sensitivity Temperature Coefficient

    -40~85°

    <150

    <150

    <150

    <150

    ppm/℃

    Frequency Response

    DC response

    100

    100

    100

    100

    Hz

    Resolution

     

    0.022

    0.022

    0.022

    0.022

    °

    Accuracy

    -40~85℃

    0.3

    0.5

    0.6

    1

    °

    Long-term Stability

    -40~85℃

    0.055

    0.063

    0.08

    0.12

    °

    Output Interface

     

    RS232、TTL、RS485、MODBUS optional

    Power-on Start Time

    Product electrical connection

    Wire color function

    Output interface

    Red

    White

    Black

    Green

    Yellow

    1

    2

    3

    4

    5

    RS232

    VCC

    NC

    GND

    RXD

     TXD

    RS485

    VCC

    NC

    GND

    (B, D-)

    (A, D+)

    TTL

    VCC

    NC

    GND

    RXD

    TXD

  • Electrical Indicators

    Parameters

    Conditions

    Minimum Value

    Typical Value

    Maximum Value

    Unit

    Supply Voltage

    Standard

    9

    12

    36

    V

    Customized

     

    5

     

    Operating Current(7)

     

     

    35

     

    mA

    Power Reverse Protection(8)

     

     

    40

     

    V

    Signal Reverse Protection(8)

     

     

    40

     

    V

    Operating Temperature

     

    -40

     

    +85

    ℃

    Storage Temperature

     

    -55

     

    +100

    ℃

  •  

    MachineMechanical Characteristics

    Connector

    Lead (1.5m) Customizable

    Torque

    <10mN.m

    Protection Level

    IP66

    Mechanical Angle

    0~360°Unlimited rotation, bidirectional rotation without stop position

    Shell Material

    Shell: Aluminum alloy oxidation, back cover: Stainless steel, shaft: Stainless steel

    Mechanical Life

    > 120 million revolutions

    Installation

    Fixed with two screws,Connected to the customer's rotor with a flexible coupling

     

     

  • Accuracy 0.3°, Resolution 0.22°

    Range 0~360° selectable

    Wide voltage input DC 9~36V

    Output interfaces RS232, TTL, RS485, MODBUS selectable

    High shock resistance >20000g

    Wide temperature operation -40~85℃

    IP66 protection level (customizable)

    Sampling rate 1K HZ