LVT532T Single Axis Single Channel Tilt Switch - Relay Type

Product performance indicators

Parameters

Conditions

LVT532T

Unit

Measurement range

 

±180

°

Measurement axis

YAxis selectable

XAxis

 

Alarm axis

YAxis selectable

XAxis

 

Frequency response

DC response

100

Hz

Resolution

Bandwidth 5Hz

0.01

°

Accuracy

-40~85℃

0.1

°

Long-term stability

-40~85℃

0.1

°

Power-on startup time

 

0.5

S

Output signal

Relay (normally open and normally closed) output, RS232, TTL, RS485 selectable simultaneously

Average working time

≥55000Hours/Times

Shock resistance

3500g,0.5ms,3Times/Axis

Vibration resistance

10grms、10~1000Hz

Insulation resistance

≥100MΩ

Waterproof rating

IP67

Cable

Standard configuration1.5 MetersLength, wear-resistant, oil-resistant, wide temperature, shielded cable5*0.3mm2

Weight

150g(Excluding packaging box)

       Product dimensions:L90*M40*H26mm

Electrical Indicators

Parameters

Conditions

Minimum Value

Typical Value

Maximum Value

Unit

Supply Voltage

Standard

9

12

36

V

Customized

 

5

 

Operating Current

 

 

20

 

mA

Maximum Current (Normally Closed)

 

 

1000

 

mA

Operating Temperature

 

-40

 

+85

℃

Storage Temperature

 

-55

 

+100

℃

Note: For other installation methods, please refer to the product manual or consult an engineer.

Accuracy 0.1°, tilt range: 0~±180°

Alarm threshold user set

Wide voltage input DC 9~36V

Switch output (normally open and normally closed)

With zero point setting

High shock resistance >3500g

Wide temperature operation -40~85℃

IP67 protection level

Size (L90*M40*H26mm) customizable

  • LVT532T is a high-performance relay output single-axis single-channel tilt switch, with a measurement range of 0~±180°. It has a built-in relay output circuit. When the tilt value exceeds the preset alarm threshold, it will output a normally open relay signal (driving current 1A) to open the solenoid valve for corresponding hydraulic leg leveling. The alarm threshold is calibrated at the factory, and users can also set the alarm angle threshold themselves.

    The product integrates imported core components, targeting applications related to horizontal safety alarms and platform leveling monitoring. It uses a transistor output circuit that can drive solenoid valves to shut down hydraulic systems, buzzers, alarm lights, etc., to automatically warn personnel for safe construction. The product design is precise, with additional compensation for temperature and linearity, and integrates comprehensive protection functions against short circuits, instantaneous high voltage, polarity, surge, etc., making it suitable for various harsh industrial environments.

    Main Features

    ● Single-axis tilt monitoring ● Full range accuracy 0.1°, resolution 0.01° ● User-settable alarm threshold ● Wide voltage input DC 9~36V

    ● Wide temperature operation -40~+85℃ ● Range 0~±180° (optional) ● High vibration resistance >3500g ● Industrial-grade design

    ● IP67 protection level ● Relay output (normally open and normally closed), simultaneously outputs RS232 ● Size (90*40*26mm) (customizable)

    Product Applications

    ● Railway gauge measuring tools, gauge instruments ● Satellite solar antenna positioning ● Tractors, deep tillage agricultural machinery ● Mining machinery, oil logging equipment ● Medical equipment

    ● Gimbal leveling ● Hydraulic lift platforms ● Based on tilt monitoring ● Angle control for various engineering machinery ● Bridge dam monitoring

  • Product performance indicators

    Parameters

    Conditions

    LVT532T

    Unit

    Measurement range

     

    ±180

    °

    Measurement axis

    YAxis selectable

    XAxis

     

    Alarm axis

    YAxis selectable

    XAxis

     

    Frequency response

    DC response

    100

    Hz

    Resolution

    Bandwidth 5Hz

    0.01

    °

    Accuracy

    -40~85℃

    0.1

    °

    Long-term stability

    -40~85℃

    0.1

    °

    Power-on startup time

     

    0.5

    S

    Output signal

    Relay (normally open and normally closed) output, RS232, TTL, RS485 selectable simultaneously

    Average working time

    ≥55000Hours/Times

    Shock resistance

    3500g,0.5ms,3Times/Axis

    Vibration resistance

    10grms、10~1000Hz

    Insulation resistance

    ≥100MΩ

    Waterproof rating

    IP67

    Cable

    Standard configuration1.5 MetersLength, wear-resistant, oil-resistant, wide temperature, shielded cable5*0.3mm2

    Weight

    150g(Excluding packaging box)

  •        Product dimensions:L90*M40*H26mm

  • Electrical Indicators

    Parameters

    Conditions

    Minimum Value

    Typical Value

    Maximum Value

    Unit

    Supply Voltage

    Standard

    9

    12

    36

    V

    Customized

     

    5

     

    Operating Current

     

     

    20

     

    mA

    Maximum Current (Normally Closed)

     

     

    1000

     

    mA

    Operating Temperature

     

    -40

     

    +85

    ℃

    Storage Temperature

     

    -55

     

    +100

    ℃

  • Note: For other installation methods, please refer to the product manual or consult an engineer.

  • Accuracy 0.1°, tilt range: 0~±180°

    Alarm threshold user set

    Wide voltage input DC 9~36V

    Switch output (normally open and normally closed)

    With zero point setting

    High shock resistance >3500g

    Wide temperature operation -40~85℃

    IP67 protection level

    Size (L90*M40*H26mm) customizable

  • File size: 2.4MB